800-343-4048

Cabinet Style PSA Nitrogen Generators

PSA (Pressure Swing Adsorption) N2 GeneratorsBalston Monobed Nitrogen Generators produce up to 99.999% pure, compressed nitrogen at dewpoints to -58°F (-50°C) from nearly any compressed air supply. The generators are designed to continually transform standard compressed air into nitrogen at safe, regulated pressures without operator attention.

Model: DBOD-10
with Trace %O2 Analyzer
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 1024
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 29
Oxygen Analyzer: Trace O2 Analyzer
Extended Cabinet: Optional
Stand By Feature: Yes

Model: DBOD-10-EC
with expandable cabinet and Trace Oxygen Analyzer. This model may be expanded to a DBOD-15 or a DBOD-20.
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 1024
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 29
Oxygen Analyzer: Trace O2 Analyzer
Extended Cabinet: Yes
Stand By Feature: Yes

Model: DBOD-15
with Trace %O2 Analyzer
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 1536
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 43.5
Oxygen Analyzer: Trace O2 Analyzer
Extended Cabinet: Optional
Stand By Feature: Yes

Model: DBOD-20
with Trace %O2 Analyzer
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 2048
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 58
Oxygen Analyzer: Trace O2 Analyzer
Extended Cabinet: Yes
Stand By Feature: Yes

Model: DBOD-5
with Trace %O2 Analyzer
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 512
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 14.5
Oxygen Analyzer: Trace O2 Analyzer
Extended Cabinet: Yes
Stand By Feature: Yes

Model: DBOD-5-EC
with expandable cabinet and Trace Oxygen Analyzer. This model may be expanded to a DBOD-10, DBOD-15 or a DBOD-20.
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 512
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 14.5
Oxygen Analyzer: Trace O2 Analyzer
Extended Cabinet: Yes
Stand By Feature: Yes

Model: MB-1
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 99
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 2.8
Oxygen Analyzer: Optional
Extended Cabinet: Optional
Stand By Feature: Optional

Model: MB-1-SB
with Standard %O2 Analyzer and Energy Saving Stand-by Feature
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 99
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 2.8
Oxygen Analyzer: Optional
Extended Cabinet: Optional
Stand By Feature: Yes

Model: MB-3
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 197
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 5.6
Oxygen Analyzer: Optional
Extended Cabinet: Optional
Stand By Feature: Optional

Model: MB-3-SB
with Standard %O2 Analyzer and Energy Saving Stand-by Feature
Nominal Flow at 99.5%, 100 psig, 7 barg - SCFH: 197
Nominal Flow at 99.5%, 100 psig, 7 barg - Nm3/hr: 5.6
Oxygen Analyzer: Optional
Extended Cabinet: Optional
Stand By Feature: Yes


© Parker Hannifin Corp 2017 
Privacy Policy | Site Map
 
 
 

Parker Hannifin Corporation
Gas Separation and Filtration Division
4087 Walden Ave.
Lancaster, NY 14086
1-800-343-4048 (US and Canada)
1-978-858-0505
Fax: 978-478-2501